Measurement: SO2, NO, CO, CO2 ,O2
Technology: SO2, NO, CO, CO2: Micro-flow NDIR O2: ECD
Rang: SO2: 0-200ppm NO: 0-200ppm CO: 0-200ppm CO2: 0-25% O2: 0-25%
Resolution: SO2, NO, CO: 1ppm CO2, O2: 0.01%
Precision: SO2, NO, CO, CO2: ±2%FS O2: ±3%FS
Gas Flow: 0.7-1.2 L/min
Inlet Pressure: 2kPa-50kPa
Sampling Gas Requirement: No dust,no moisture.
Response Time: <15s (NDIR)
Warm-up Time: 800s
Communication Port: RS-232/RS-485
Output: 4-20mA
Work Temperature: 0-50℃
Relative Humidity: 0-95% non condensing
Ambient Air Pressure: 86-108kPa
Power Supply: 220V±44V AC 50Hz±1Hz
Dimension: 483*373*140 mm (W*L*H)
Weight: 15kgs
Adopting micro-flow NDIR gas sensor technology, higher precision and longer life time.
Monitoring the loweer range of SO2, NO, CO within 200ppm.
No cross interference between measurement gases.
Diagnostic function can check sensor status.
Sampling flow rate fluctuations have no effect on the measurement results.
Accurate measurement of low concentration gas.
Built-in pump to achieve automatic zeroing.
Real-time continuous monitoring concentration of SO2, NO, CO, CO2, O2 , measurement component is optional.
LCD (320*240) display.
Digital and analog signal output.